TitleProduct

Vacuum Lamp

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2020-12-17 13:00

  • Browse the number:

    278

Send an inquiries

Company Profile

Zhejiang Setec Co., Ltd

By certification [File Integrity]

Contact:skgjmy(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.setecvac.com/ http://skgjmy.whdxwjd.com/

Product Details


FU-836F or FU-836FA is metal ceramic triode, directly heated Thorium tungsten cathode triode. The anode cooled by forced air. The anode dissipation power 30kW, the output power can up to 30kW when the frequency is less than 60MHz.The tube is mainly used as the amplifier and oscillator in industrial high frequency medium heating equipment.


Electrical Characteristics:

Filament Voltage

10V

Filament Current

200A

(Ia=0.2A) Transconductance

≥60mA/V

Amplification factor

25

Interelectrode Capacitances

Grid-Anode

43.5pF

Grid-Filament

86pF

Filament-Anode

3.4pF

Weight

14.6kg

Operating position

Vertical anode up

Cooling

Forced air

Anode cooling air flow

1500m³/h

Air flow on stem

80m³/h

Max temperature at any point tube envelope

250℃


Limit Working Conditions:

Max Frequency

30MHz

DC Anode Voltage

12kV

DC Grid Voltage

-1500V

Anode dissipation

30kW

Grid dissipation

1000W

DC Anode current

8A

DC Grid current

2A


Typical Operation:

Frequency

30MHz

Filament voltage

10V

DC Anode Voltage

10kV

DC Grid Voltage

--850V

Grid RF peak voltage

1200V

DC anode current

7.5A

DC Grid current

1.2A

Output power

60kW


Dimension(mm):

Caution for the use:

1.While move and install the Electron Tube, should be put very carefully, strong vibration and been struck is forbidden.

2.Electron Tube should be stored in the dry place, the temperature should above -5℃. For long-term preservation, it should be better sealed in plastic bags and put some dry desiccant in.

3.Prevented from the extraneous matters contaminated the surface of the Electron Tube, especially the ceramics and the glasses part of the Electron Tube.

4.Electron tube and the vacuum chamber, valve socket are the constituent parts. They must be tight junction. While replace Electron Tube, should check if the leaf spring is still tight junction. If there is deformation, loose, fall off, it should be repaired immediately.


http://www.setecvac.com/